PRODUCT GROUP9900U<15K
MATERIALSS316LStainless steel

NPT Male Hex Socket Plug

ASME B1.20.1

Working pressure varies by size - see table*

9900U 15K NPT Male Hex Socket Plug dimensional drawing

Dimensions & variants

Dimensions in mm

Item numberNPT ThreadAHexWorking pressure
99000202U3161/8"NPT8415,000 PSI / 1,034 bar / 103.4 MPa
99000404U3161/4"NPT12615,000 PSI / 1,034 bar / 103.4 MPa
99000606U3163/8"NPT12815,000 PSI / 1,034 bar / 103.4 MPa
99000808U3161/2"NPT161015,000 PSI / 1,034 bar / 103.4 MPa
99001212U3163/4"NPT161215,000 PSI / 1,034 bar / 103.4 MPa
99001616U3161"NPT201715,000 PSI / 1,034 bar / 103.4 MPa
99002020U3161 1/4"NPT201710,000 PSI / 689 bar / 68.9 MPa
99002424U3161 1/2"NPT202210,000 PSI / 689 bar / 68.9 MPa
99003232U3162"NPT202710,000 PSI / 689 bar / 68.9 MPa

Article number structure

9900 | 08 | 08 | U | 316

Series | NPT thread code | NPT thread code | Hex socket version | Material

Download Datasheet

Product specifications

Connection — NPT MaleConfigurationGeneral product information
Type
NPT Male
Sealing
Tapered pipe thread
Thread standard
ASME B1.20.1
Type
Hex socket plug
Connections
One threaded connection
Sizes
See dimensions
Working pressure
10,000–15,000 PSI; see table*
HS code
73079900
Country of origin
Norway

Technical info

Connections

NPT side: Tapered pipe thread to ASME B1.20.1. Hex socket drive for compact installation. Working pressure is size-dependent and is specified individually in the table.

Working pressure basis*

The stated working pressure is based on Intermec's established design calculations, dimensional design criteria and more than 35 years of experience with high-pressure fittings in demanding offshore and oil & gas applications. Suitability depends on correct installation, mating connection, material and operating conditions.

IM-9900U-15K · HTML DRAFT 01
Layout example based on the group 9900U datasheet.
Information may contain errors or omissions and is subject to change without notice. Verify current specifications and suitability for the intended application before use. Contact Intermec if any information is unclear or inconsistent.