Light Series (L) · Heavy Series (S) · ISO 8434-1 connection family · Material SS316L
Connection of a metric 24° female swivel end to a matching male connection. Match the thread, tube-size reference and L or S series on both components. This page concerns the threaded connection; hose crimping and cutting-ring assembly require separate instructions.
Isolate and fully depressurise the system. Confirm the exact sealing design against the product drawing. Use suitable spanners, a calibrated torque wrench and the approved lubricant compatible with the seal and service fluid.
Schematic illustrations · not to scale
Clean both components. Inspect threads, cone surfaces and any specified O-ring for contamination or damage. Replace damaged components before assembly.
Apply the lubricant specified for the exact component combination. Align the connection without side load. Do not apply thread-sealing tape to this cone-sealed connection.
Start the swivel nut by hand. Ensure smooth engagement and correct seating without forcing the connection. Keep the hose in its intended position without twisting.
Hold the mating body with a backup spanner. Tighten the swivel nut using the released, product-specific SS316L procedure and value. Do not use the reference tables below for assembly.
Parker reference · zinc-plated steel · Nm
| Thread | Tube ع | Nominal | Range |
|---|---|---|---|
| M12 × 1.5 | 6 | 16 | 15–17 |
| M14 × 1.5 | 8 | 16 | 15–17 |
| M16 × 1.5 | 10 | 26 | 25–28 |
| M18 × 1.5 | 12 | 37 | 35–39 |
| M22 × 1.5 | 15 | 47 | 45–50 |
| M26 × 1.5 | 18 | 89 | 85–94 |
| M30 × 2 | 22 | 116 | 110–121 |
| M36 × 2 | 28 | 137 | 130–143 |
| M45 × 2 | 35 | 226 | 215–237 |
| M52 × 2 | 42 | 347 | 330–363 |
Parker reference · zinc-plated steel · Nm
| Thread | Tube ع | Nominal | Range |
|---|---|---|---|
| M14 × 1.5 | 6 | 26 | 25–28 |
| M16 × 1.5 | 8 | 42 | 40–44 |
| M18 × 1.5 | 10 | 53 | 50–55 |
| M20 × 1.5 | 12 | 63 | 60–66 |
| M22 × 1.5 | 14 | 79 | 75–83 |
| M24 × 1.5 | 16 | 84 | 80–88 |
| M30 × 2 | 20 | 126 | 120–132 |
| M36 × 2 | 25 | 179 | 170–187 |
| M42 × 2 | 30 | 263 | 250–275 |
| M52 × 2 | 38 | 368 | 350–385 |
¹ Tube outside-diameter reference in mm; not hose bore. The same thread can occur in different series. Do not select a connection or tightening value by thread alone.
Check alignment, hose twist and visible damage. Complete the specified system leak test under controlled conditions. Never check for leaks by hand or tighten a pressurised connection.
Fully depressurise before loosening. Inspect the mating surfaces and seals. Follow the released seal-replacement and reassembly procedure; this draft does not authorise reuse or specify retightening values.
Need connection-specific assistance?
Send the article number, mating connection and service conditions.
Contact IntermecSource for table data: Parker Technical Handbook, Bulletin C4400-A/UK, Ab-23 (PDF page 67). Instructions and schematic illustrations are an Intermec layout draft requiring technical review. This page is not released for installation or service.