PRODUCT GROUPHMF930015K
MATERIALSS316LStainless steel

High Pressure Male Fixed × NPT Male

ASME B1.20.1

Rated working pressure: 15,000 PSI / 1,034 bar / 103.4 MPa*

HMF9300 15K High Pressure Male Fixed × NPT Male dimensional drawing

Dimensions & variants

Dimensions in mm

Item numberHP SizeHP ThreadNPT ThreadABCHex
HMF930004043161/4" (04)9/16"-18UN1/4"NPT41.5161417
HMF930004063161/4" (04)9/16"-18UN3/8"NPT44161519
HMF930004083161/4" (04)9/16"-18UN1/2"NPT49161922
HMF930006043163/8" (06)3/4"-16UN1/4"NPT44231417
HMF930006063163/8" (06)3/4"-16UN3/8"NPT46231519
HMF930006083163/8" (06)3/4"-16UN1/2"NPT51231922
HMF930009043169/16" (09)1 1/8"-12UN1/4"NPT50271422
HMF930009063169/16" (09)1 1/8"-12UN3/8"NPT51271522
HMF930009083169/16" (09)1 1/8"-12UN1/2"NPT55271922

Article number structure

HMF9300 | 09 | 08 | 316

Series | HP size code | NPT size code | Material

Download Datasheet

Product specifications

End 1 — High Pressure Male FixedEnd 2 — NPT MaleGeneral product information
Type
High Pressure Male Fixed
Sealing
58° male cone / 60° female cone seat
Connection geometry
High Pressure cone-and-thread
HP size and thread
See dimensions
Type
NPT Male
Sealing
Tapered pipe thread
Thread standard
ASME B1.20.1
Working pressure
15,000 PSI / 1,034 bar / 103.4 MPa*
HS code
73079900
Country of origin
Norway

Technical info

Connections

High Pressure side: 58° male cone geometry, mating against a 60° female cone seat.

NPT side: Tapered pipe thread to ASME B1.20.1.

Dimensionally compatible with the established High Pressure cone-and-thread connection geometry.

Working pressure basis*

The stated working pressure is based on Intermec's established design calculations, dimensional design criteria and more than 35 years of experience with high-pressure fittings in demanding offshore and oil & gas applications. Suitability depends on correct installation, mating connection, material and operating conditions.

IM-HMF9300-15K · HTML DRAFT 01
Layout example based on the group HMF9300 datasheet.
Information may contain errors or omissions and is subject to change without notice. Verify current specifications and suitability for the intended application before use. Contact Intermec if any information is unclear or inconsistent.