PRODUCT GROUPHF860015K
MATERIALSS316LStainless steel

High Pressure Female × JIC 37° Female Fixed

ISO 8434-2

Rated working pressure: 15,000 PSI / 1,034 bar / 103.4 MPa*

HF8600 15K High Pressure Female × JIC 37° Female Fixed dimensional drawing

Dimensions & variants

Dimensions in mm

Item numberHP SizeHP ThreadJIC 37° ThreadDashAHex
HF860004073161/4" (04)9/16"-18UN7/16"-20UN-043022
HF860004093161/4" (04)9/16"-18UN9/16"-18UN-063022
HF860006073163/8" (06)3/4"-16UN7/16"-20UN-043230
HF860006093163/8" (06)3/4"-16UN9/16"-18UN-063230
HF860006123163/8" (06)3/4"-16UN3/4"-16UN-083430
HF860009073169/16" (09)1 1/8"-12UN7/16"-20UN-044636
HF860009093169/16" (09)1 1/8"-12UN9/16"-18UN-064636
HF860009123169/16" (09)1 1/8"-12UN3/4"-16UN-084836

Article number structure

HF8600 | 09 | 12 | 316

Series | HP size code | JIC size code | Material

Download Datasheet

Product specifications

End 1 — High Pressure FemaleEnd 2 — JIC FeMale FixedGeneral product information
Type
High Pressure Female
Sealing
60° female cone seat
Connection geometry
High Pressure cone-and-thread
HP size and thread
See dimensions
Type
JIC FeMale Fixed
Sealing
37° flare
Connection standards
ISO 8434-2
Thread standard
ASME B1.1
Working pressure
15,000 PSI / 1,034 bar / 103.4 MPa*
HS code
73079900
Country of origin
Norway

Technical info

Connections

High Pressure side: 60° female cone seat, intended to mate with a 58° male cone.

JIC side: 37° female flare connection to ISO 8434-2 with UN/UNF thread to ASME B1.1. JIC dash size is shown in the table.

Dimensionally compatible with the established High Pressure cone-and-thread connection geometry.

Working pressure basis*

The stated working pressure is based on Intermec's established design calculations, dimensional design criteria and more than 35 years of experience with high-pressure fittings in demanding offshore and oil & gas applications. Suitability depends on correct installation, mating connection, material and operating conditions.

IM-HF8600-15K · HTML DRAFT 01
Layout example based on the group HF8600 datasheet.